Problem / challenges Faced
The Nuclear Power plant was facing frequent vibration and failure of Imported Foreign brand.
Operating Parameters / Specifications
Fluid: DM water
CV-1500
Valve size-14”
Rating: 300#
End connection: Butt Weld
Expander/ Reducer size: 14”x22” and 22”x14”
Actuator: Electric actuator
Design Solution :
We offered our ‘HF’ valve with CV-1500 and provide provision in cage for drilling additional holes -25% space in case there is any requirement in site at future.
Different grades of Colmonoy applied at plug and seat face for getting required hardness.
The design is validated for natural frequency, static loading and flow test using in house analysis capabilities, help us to achieve the results at first time.
The test valve is welded in house with reducer and expander and the entire valve system undergoes all test and met the desired values.
The Indigenous Electrical actuator vendor is developed by us.
Benefit – The end customer benefitted as the control valve with our designed valve is worked without shutdown and Indigenous valve and electric actuator cause significant reduction in spare cost. The additional provision of holes in cage help to use same valve with minimum modification in cage to meet additional flow requirement in future.
Reduction in costs of Imported Spares / Trims.
Economics : Was about 40 % Lower than earlier Imported Variant